adoptionNDIR(non-dispersive infrared absorption)Technical principle for fixing carbon dioxide in the sourceCO2Real - time on - line monitoring and management of concentration and volume. Instrument satisfiesHJ/T 870-2017Determination of Carbon Dioxide in Waste Gas from Fixed Pollution Sources by Non - Dispersive Infrared Absorption Method,T/CAS 454-2020"Online monitoring and technical requirements for carbon dioxide emission of thermal power generation enterprises,"DL/T2376-2021"Technical Specification for Continuous Monitoring of Flue Gas Carbon Dioxide Emission of Thermal Power Plant," the monitoring data can display and automatically record the monitoring date, time and temperature,CO2the volume concentration,CO2mass concentration, flow(Dry flue gas volume under standard conditions), flue gas static pressure, flue gas humidity, oxygen content and other monitoring values, which can be converted into pollution sourcesCO2Total emissions( t/hOr,t/d )。
Technical Parameters | TP-300-YCL type stationary source CO2 gas on-line monitor |
sampling method | cold-dry extraction sampling |
gas range | 0-10000ppm (Can be adjusted according to requirements) |
Temperature limit of source gas | 0-600℃(customizable) |
Compressed air requirements for the whole system | 0.4MpaAbove, no oil, no water |
gas flow rate | ≤2L/min |
zero drift | ≤±2%FS./Zhou |
linearity error | ≤±2%FS./Zhou |
power supply | 220VACor12-24VDC,>3000W |
Output signal | RS232digital signals/4Gwireless transmission, support(HJ/T212)or modbuscommunication protocols |
operating temperature | -20℃-80℃ |
working humidity | 5%-80% RH |
working pressure | 0.8-1.2 ATM |
external dimension | approx. length330mm×width217mm×high430mm(or customized to your needs) |
Material of shell | spray moulding of galvanized steel plate(The weight of the whole machine is approx.17Kg) |